Littelfuse PGR-8800-00 Arc-Flash Relay
VAT incl.
Subscription
00,00 €*
00,00 €*
previously 0
PGR-8800-00 Protection Relays and Controls Arc-Flash Monitoring.
Art
406000410
Sn Pcs
PGR-8800-00
Manufacturer
Littelfuse Europe
Non disponibile
icon
After-sales support
icon
Stock availability
Description
Description
Littelfuse PGR-8800-00 Arc-Flash Relay
The PGR-8800 is a microprocessor-based relay that limits arc-fault damage by detecting the light from an arc flash and rapidly tripping. Phase-current-transformer inputs are provided for current-constrained arc-flash protection and, when so equipped, a programmable definite-time overcurrent function can be enabled. An optical sensor on the PGR-8800 and adjustable trip level reduce the chance of nuisance tripping by setting a threshold for ambient light. Sensors, inputs, and connections are monitored to ensure fail-safe operation. A secondary solid-state trip circuit provides a redundant trip path. A USB port is used for configuration and access to event logs and graphs.
Relay Contacts Config 3 Form C (N.O./N.C.); 1 Form A (N.O.) Supply Voltage ac 120 / 240 Supply Voltage dc 12 - 48 / 120 / 240 IEEE Device Numbers 50 - AFD Relay Contacts Operation Fail-safe / Non Fail-safe Dimensions 5.2 H x 7.9 W x 2.2 D in. Weight (lbs/g) 0.6 Kg Auto Manual Reset Latching Frequency 50; 60; ASD Reset Type Front-panel switch/Two Remote Contacts System type Solidly Grounded AC; Resistance Grounded AC; Ungrounded AC Test Button Front-panel switch; Two remote contacts Digital Inputs 6
The PGR-8800 is a microprocessor-based relay that limits arc-fault damage by detecting the light from an arc flash and rapidly tripping. Phase-current-transformer inputs are provided for current-constrained arc-flash protection and, when so equipped, a programmable definite-time overcurrent function can be enabled. An optical sensor on the PGR-8800 and adjustable trip level reduce the chance of nuisance tripping by setting a threshold for ambient light. Sensors, inputs, and connections are monitored to ensure fail-safe operation. A secondary solid-state trip circuit provides a redundant trip path. A USB port is used for configuration and access to event logs and graphs.
Relay Contacts Config 3 Form C (N.O./N.C.); 1 Form A (N.O.) Supply Voltage ac 120 / 240 Supply Voltage dc 12 - 48 / 120 / 240 IEEE Device Numbers 50 - AFD Relay Contacts Operation Fail-safe / Non Fail-safe Dimensions 5.2 H x 7.9 W x 2.2 D in. Weight (lbs/g) 0.6 Kg Auto Manual Reset Latching Frequency 50; 60; ASD Reset Type Front-panel switch/Two Remote Contacts System type Solidly Grounded AC; Resistance Grounded AC; Ungrounded AC Test Button Front-panel switch; Two remote contacts Digital Inputs 6
Technical features
| SKU | 406000410 |
| AVG leadtime (calendar days) | 70 |
| Country of origin | 46 |
| Eu Tariff Code (TARIC) | 85364900 |
| External Height | 130.00 mm |
| External length | 200.00 mm |
| External Width | 54.00 mm |
| Manufacturer Part Number | PGR-8800-00 |
| Model | SPD2-300-M |
| Net weight | 0.60 kg |
| Selling quantity | 1 |
| Selling UoM | PZ |
| Short Description | PGR-8800-00 Protection Relays and Controls Arc-Flash Monitoring. |
| SIAE | 0 |